• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Thu, 26.12.24

Search results


April 2009
D. Dvir, A. Assali, H. Vaknin, A. Sagie, Y. Shjapira, A. Battler, E. Porat and R. Kornowski

The incidence of aortic valve stenosis is growing rapidly in the elderly. Nonetheless, many symptomatic patients are not referred for surgery usually because of high surgical risk. Unfortunately, percutaneous balloon valvuloplasty is unsatisfactory due to high recurrence rates. In 2002, Cribier and colleagues were the first to describe percutaneous aortic valve implantation, opening a new era of aortic stenosis management. In the present review we report a patient treated by this novel method, discuss and assess how it is implanated, report the findings of studies conducted to date, and suggest future directions for percutaneous treatment of aortic valve disease.
 

September 2008
R. Kornowski, G. N. Bachar, D. Dvir, S. Fuchs and E. Atar

Background: Cardiac computed tomography angiography is a relatively new imaging modality to detect coronary atherosclerosis.

Objectives: To explore the diagnostic value of CTA[1] in assessing coronary artery disease among asymptomatic patients.

Methods: In this retrospective single-centered analysis, 622 consecutive patients underwent CTA of coronary arteries between November 2004 and May 2006 at the Mor Institute for Cardiovascular Imaging in Bnei Brak, Israel. All patients were asymptomatic but had at least one risk factor for atherosclerotic CAD[2]. The initial 244 patients were examined with the 16-slice Brilliance CT scanner (Philips, Cleveland, OH, USA), and in the remaining 378 patients the 64-slice scanner (GE Healthcare, The Netherlands) with dedicated cardiac reconstruction software and electrocardiography triggering was used. Scanning was performed in the cranio-caudal direction. Images reconstructed in different phases of the cardiac cycle using a retrospective ECG-gated reconstruction algorithm were transferred to a dedicated workstation for review by experienced CT radiologists and cardiologists.

Results: Of 622 patients, 52 (8.4%) had severe obstructive atherosclerosis (suspected ≥ 75% stenosis) according to CTA interpretation. Invasive coronary angiography was performed in 48 patients while 4 patients had no further procedure. A non-significant CAD (e.g., diameter stenosis < 70%) was identified in 6 of 48 patients (12%) by selective coronary angiography. Forty-two patients showed severe CAD with at least one lesion of ≥ 70% stenosis. Percutaneous coronary intervention was performed in 35 patients and coronary artery bypass grafting surgery in the other 4 patients. Angioplasty procedures were successful in all 35 patients and stents were utilized in all cases without complications. No further complications occurred among the study cohort undergoing either PCI[3] or surgery. The 6 month survival rate in these patients was 100%.

Conclusions: Non-invasive coronary CTA appears to be a reliable technique, with reasonably high accuracy, to detect obstructive atherosclerosis in asymptomatic high risk patients for atherosclerotic CAD.






[1] CTA = computed tomography angiography

[2] CAD = coronary artery disease

[3] PCI = percutaneous coronary intervention


April 2007
R. Beigel, S. Matetzky, P. Fefer, D. Dvir and H. Hod
July 2005
T. Gaspar, D. Dvir and N. Peled
 Background: Computed tomography angiography enables non-invasive evaluation of the coronary arteries.

Objectives: To evaluate the accuracy of 16-slice multi-detector CT angiography in the diagnosis of coronary artery disease, and assess coronary bypass grafts and coronary anomalies.

Methods: We conducted a retrospective study of 223 patients who were examined at our medical center over a period of 2 years with a 16-slice CT angiography scanner and retrospective electrocardiographic gating.

Results: There were no significant complications, and good visualization of the coronary arteries was achieved in all but eight patients. A high correlation with the results of the invasive angiography was noted (sensitivity 85%, specificity 93%, negative predictive value 98%). Altogether, 131 bypass conduits were examined with excellent graft visualization. Several coronary anomalies were detected, as were significant extra-cardiac findings.

Conclusions: Multi-slice CT angiography is a reliable non-invasive diagnostic procedure for demonstration of the coronary arteries and bypass grafts. In the future it will probably replace part of the diagnostic invasive coronary angiography and, as a result, a large proportion of coronary angiography procedures will be therapeutic.

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel